MITSUBISHI A1SJ51T64  User's Manual PDF

Brand: MITSUBISHI
Product model: A1SJ51T64 
Name: I/O Link Remote I/O System Master Module
Sort: User's Manual
File language: English
File size: 2.04MB
Output type: transistor output, source.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 A1SJ51T64  PDF. 5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1SJ51T64  32 point connector for compression connector (37 pin D-sub connector) A1SJ51T64  PDF. Input type: DC input, negative publlic end A1SJ51T64  Manual.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector A1SJ51T64  PDF.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Data format: ASCII.
Data bits: 7.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing MITSUBISHI User's Manual.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components.
This feature makes the main station of the data acquisition and control with more flexibility MITSUBISHI User's Manual.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII. Output type: transistor output, drain typee A1SJ51T64  User's Manual.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No MITSUBISHI User's Manual.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
A2C shape terminal.
Type of input and output terminal A1SJ51T64  Manual.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required.