MITSUBISHI A1SJ71QC24-R2 User's Manual PDF

Brand: MITSUBISHI
Product model: A1SJ71QC24-R2
Name: Communications Module
Sort: User's Manual
File language: English
File size: 0.41MB
Category: slave station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m A1SJ71QC24-R2 PDF.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add A1SJ71QC24-R2
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations A1SJ71QC24-R2 PDF. A3VTS using the basic unit.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a ccurrent flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A1SJ71QC24-R2 PDF A1SJ71QC24-R2 Manual .
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action MITSUBISHI User's Manual.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program MITSUBISHI User's Manual.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity annd switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI User's Manual A1SJ71QC24-R2 User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A1SJ71QC24-R2 Manual .
The following describes the centralized control system I/O points of the estimate.