MITSUBISHI A1SX42 User's Manual PDF

Brand: MITSUBISHI
Product model: A1SX42
Name: I/O Module
Sort: User's Manual
File language: English
File size: 5.14MB
Input voltage range: AC100 ~ 120V.
Output voltage: DC24V.
Output current: 0.6A.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A1SX42 PDF.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A1SX42
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action A1SX42 PDF.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A1SX42 PDF.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30% MITSUBISHI User's Manual.
The following describes the centralized control systeem I/O points of the estimate A1SX42 Manual. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function MITSUBISHI User's Manual.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read MITSUBISHI User's Manual.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators A1SX42 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A1SX42 Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
32: terminal line adapter
A1S-TA32
MITSUBISHI 32: terminal line adapter A1S-TA32
32: terminal line adapter 0.3mm2 AGW22.
MITSUBISHI
Input / output module
A1SX48Y58
MITSUBISHI Input / output module A1SX48Y58
Type of input: DC leakage. Input points: 8 po
MITSUBISHI
Network module
A1SJ72QLP25
MITSUBISHI Network module A1SJ72QLP25
SI/QSI/H-PCF/ wide H-PCF optical cale dual l
MITSUBISHI
Pulse output positioning control module
A1SD71-S2
MITSUBISHI Pulse output positioning control module A1SD71-S2
Axis of control: 2. A1SD71-S2 is a linear int