Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 16 points A2NCPUR21 PDF.
Output voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
16 point /1 a public side.
Output type: transistor output (type sink).
With the surge absorber.
50 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A2NCPUR21
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A2NCPUR21 PDF.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A2NCPUR21 PDF. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian MITSUBISHI User's Manual.
It uses a kind of prrogrammable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI User's Manual A2NCPUR21 Manual .
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI User's Manual. Description: through the 0~100m infrared space transmission, optical communication status monitoring function.
Station type: take up 1 stations for the remote I/O.
Spare 5 products for different purposes.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof structure.
Sppring clip terminal type relay hub A2NCPUR21 User's Manual.
Star type wiring, length of the main line, spring clamping terminal table type.
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line A2NCPUR21 Manual .
Relay unit in space light.
Communication between linear moving bodies.
Related products
MITSUBISHI
CPU unit
A2NCPUR21
MITSUBISHI CPU unit A2NCPUR21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A3NCPUR21
MITSUBISHI CPU unit A3NCPUR21
Input and output points: 2048 points. Input /
MITSUBISHI
CPU unit
A2NCPUP21
MITSUBISHI CPU unit A2NCPUP21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2NCPU
MITSUBISHI CPU unit A2NCPU
Input and output points: 512 points. Input /