Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Coaxial data communication line function A3NMACA4-UL PDF.
It is possible for AnNCPU to use ACPU as a sequential program.
The order of the ACPU program is to the following command;
In addition to a special broadcast on that can be used with AnNCPU.
User program storage capacity: it is a measure of how much the user application can store the number of indicators
A3NMACA4-UL
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words A3NMACA4-UL PDF. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A3NMACA4-UL PDF.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance. Output type: relay output MITSUBISHI User's Manual.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI User's Manual.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. PLC station distance: 1Km.
Cable type: QSI-200/250.
The function of the MELSECNET interface module is to connect the main CPU PLC to the MELSECNET data communication system MITSUBISHI User's Manual.
As long as the switch on the component to set, you can determine the CPU PLC is as a main station or in situ station.
There are two modules available for selection: one is the connection of the optical cable network and the network of the coaxial cable.
For a ANSCPU, up to only a piece of interface components can be inserted, A2ASCPU can be inserted 2.
The popularization andd application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment A3NMACA4-UL Manual .
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming languaage is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-tto-one correspondence between the ladder diagram and the ladder diagram A3NMACA4-UL Manual A3NMACA4-UL User's Manual. Its characteristics are basically consistent with the ladder diagram language.