Output points: 16 points.
Voltage: DC5/12V.
Output type: Sink type.
Response time: 1ms.
8 points / a common end.
20 point terminal station.
Each scanning process AJ71QLP21S PDF. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read
AJ71QLP21S
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AJ71QLP21S PDF.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i AJ71QLP21S PDF. e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, appplicable occasions also have different emphasis,
Price also has a greater difference MITSUBISHI User's Manual AJ71QLP21S Manual . Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. RS-232C connection (QnA/A/FXCPU direct connection, computer connection, micro computer connection) MITSUBISHI User's Manual.
No clock function.
Applicable model: A956WGOT. RS-422 1 channel.
Transfer speed: 38.4kbps.
Link points, 512 points.
The connection number: 8, 500m.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHII PLC,
To determine the I/O PLC points AJ71QLP21S User's Manual.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book AJ71QLP21S Manual .