MITSUBISHI AX80-UL User's Manual PDF

Brand: MITSUBISHI
Product model: AX80-UL
Name: PLC
Sort: User's Manual
File language: English
File size: 0.41MB
Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DC5V output 2A DC24V/ AX80-UL PDF.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units AX80-UL 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words AX80-UL PDF. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Prrovide load current and voltage AX80-UL PDF AX80-UL Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action MITSUBISHI User's Manual. Capable of continuous thermocouple or platinum temperature measurement.
In addition, the temperature measurement range can be set with the use of the temperature.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI User's Manual MITSUBISHI User's Manual.
The response time of PLC is the interval between the time of the change of the external output signal of the PLLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AX80-UL Manual AX80-UL User's Manual.
This phenomenon is called the I/O delay time effect.
Related products
MITSUBISHI
DC input / relay output module
AX80Y14CEU
MITSUBISHI DC input / relay output module AX80Y14CEU
Input points: 16 points. Input voltage and cu
MITSUBISHI
Input module
AX81-S2
MITSUBISHI Input module AX81-S2
Input points: 32 points. Voltage: DC48/60V. C
MITSUBISHI
DC input / relay output module
AX80Y10C
MITSUBISHI DC input / relay output module AX80Y10C
Input points: 16 points. Input voltage and cu
MITSUBISHI
Input module
AX80E
MITSUBISHI Input module AX80E
Input points: 16 points. Voltage: DC12/24V. C