Brand: MITSUBISHI
Product model: AY42-S4
Name: I/O Module
Sort: User's Manual
File language: English
File size: 3.29MB
Output type: relay output.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A AY42-S4 PDF.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AY42-S4 Cable length: 6CM.
For functional connectivity (horizontal extension) GOT (D-sub 25 male and) RS422 cable pins: (D-sub 25 female pins:) connection AY42-S4 PDF. Cable length: 5 meters.
For connection between GOT and CRT. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 16 points AY42-S4 PDF.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid vaalve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI User's Manual MITSUBISHI User's Manual AY42-S4 Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmissionn device, brake signal and fan fault signal AY42-S4 User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AY42-S4 Manual.
Related products
MITSUBISHI
Transistor output module
AY42-S4
MITSUBISHI Transistor output module AY42-S4
Output points: 64 points. Voltage: DC12/24V.
MITSUBISHI
Optical media conversion
A6BSW-P-S4
MITSUBISHI Optical media conversion A6BSW-P-S4
Self service IN, OUT: SI optical cale. Oth
MITSUBISHI
CPU unit
A2ACPUP21-S4
MITSUBISHI CPU unit A2ACPUP21-S4
Input and output points: 1024 points. Input /
MITSUBISHI
Transistor output module
AY41
MITSUBISHI Transistor output module AY41
Output points: 32 points. Voltage: DC12/24V.