MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 2.2KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FR-A740-500K-CHT PDF
FR-A740-500K-CHT
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A740-500K-CHT PDF FR-A740-500K-CHT Manual .
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. Length: 0.1m.Max input / output points: 14 points FR-A740-500K-CHT PDF.
Power supply voltage: DC24V.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control MITSUBISHI TECHNICAL MANUAL.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device MITSUBISHI TECHNICAL MANUAL.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The seriees transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor FR-A740-500K-CHT TECHNICAL MANUAL.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amoount of I/O MITSUBISHI TECHNICAL MANUAL FR-A740-500K-CHT Manual .
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.