Power: 7.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed FR-V540-30K-CH PDF. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table
FR-V540-30K-CH
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used FR-V540-30K-CH PDF. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Applicable models: FX3G\FX3GE\FX3GC\FX3U\FX3UC FR-V540-30K-CH PDF.
The contents of the RAM memory in FX2N-10GM, FX3UC, FX2N-20GM and FX3U are built up.
In addition, it is also required to use the backup relay and the data register and the time of the data register.
As FX3G, FX3GE, FX3GC with the option,
The use oof soft components other than EEPROM MITSUBISHI INSTRUCTION MANUAL FR-V540-30K-CH Manual. Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI INSTRUCTION MANUAL. ) Total input and output points: 8 points.
Output points: 8 points.
Output type: transistor output.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect MITSUBISHI INSTRUCTION MANUAL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit.
FX Series in the compact body built in superior performance, and strive to operatee simple FR-V540-30K-CH INSTRUCTION MANUAL.
In addition, rich options can meet the various needs of customers.
In the virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can bbe extended to all models in the FX series analog devices FR-V540-30K-CH Manual.
Function extension board, special adapter without programming can be used for communication.