LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX3G-40MT/DSS USER'S MANUAL (Positioning Control Edition) PDF

MITSUBISHI FX3G-40MT/DSS USER'S MANUAL (Positioning Control Edition) PDF

Brand: MITSUBISHI
Product model: FX3G-40MT/DSS
Name: PLC
Sort: USER'S MANUAL (Positioning Control Edition)
File language: English
File size: 5.86MB
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Can monitor and change the value of the soft component FX3G-40MT/DSS PDF. Can also be simple to operate, change the data.
Can display Japanese and english.
Can be installed directly to the PLC, no wiring.
In addition, the use of FX3U-7DM-HLD, can be directly installed on the electrical cabinets FX3G-40MT/DSS Input / output form: relay output.
Output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 75mA.
In order to extend the input output of the device FX3G-40MT/DSS PDF.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Max input / output points: 60 points FX3G-40MT/DSS PDF.
Supply voltage: 100 - 240VAC.
Input points: 36 points.
Output points: 24 points.
Output type: relay.
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
Rich functionality.
FX series of products are rich in variety, users can be based on cost or application,
Choose the most suitable product MITSUBISHI USER'S MANUAL. Will find a suitable model for the user site.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed MITSUBISHI USER'S MANUAL.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V MITSUBISHI USER'S MANUAL.
Frequency converter capacity: 185KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FX3G-40MT/DSS Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mmainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3G-40MT/DSS USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3G-40MT/DSS Manual. "
Related products
MITSUBISHI
RS-485 expansion board
FX3G-485-BD
MITSUBISHI RS-485 expansion board FX3G-485-BD
Function expansion oard for RS-485 communica
MITSUBISHI
PLC
FX3U-32MT/DSS
MITSUBISHI PLC FX3U-32MT/DSS
Max input / output points: 32 points. Power s
MITSUBISHI
PLC
FX3U-80MT/DSS
MITSUBISHI PLC FX3U-80MT/DSS
Max input / output points: 80 points. Power s
MITSUBISHI
PLC
FX3U-48MT/DSS
MITSUBISHI PLC FX3U-48MT/DSS
Max input / output points: 48 points. Power s