Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 30VA FX3U-80MT/ES-A PDF.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module
FX3U-80MT/ES-A
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register FX3U-80MT/ES-A PDF.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communicationns
Password protection, using a eight digit password to protect your program FX3U-80MT/ES-A PDF FX3U-80MT/ES-A Manual.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time MITSUBISHI USER'S MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: transistor.
Power consumption: 40VA MITSUBISHI USER'S MANUAL.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate MITSUBISHI USER'S MANUAL.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, ussing a eight digit password to protect your program FX3U-80MT/ES-A USER'S MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX3U-80MT/ES-A Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).