MITSUBISHI LD77MS16 User's Manual (Positioning control) PDF

Brand: MITSUBISHI
Product model: LD77MS16
Name: Simple Motion Module
Sort: User's Manual (Positioning control)
File language: English
File size: 7.50MB
DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output LD77MS16 PDF.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable LD77MS16
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quantity, temperature and humidity terminal, anti false operation terminal and other equipment LD77MS16 PDF.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / output 512 points) of the I/O control.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km LD77MS16 PDF. Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period MITSUBISHI User's Manual.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set MITSUBISHI User's Manual.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of mmonitoring and testing functions, you can simply start and action check LD77MS16 Manual .
Can only choose the necessary items from the rich monitoring information and monitor the display MITSUBISHI User's Manual.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Output points: 16 points.
Output form: bidirectional thyristor output.
Rated output voltage: AC100 ~ 240V.
Max load current: 0.6A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge prottection function, with 3000V photoelectric isolation LD77MS16 User's Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible LD77MS16 Manual .
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.