LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02CPU User's Manual (Hardware Design, Maintenance and Inspection) PDF

MITSUBISHI Q02CPU User's Manual (Hardware Design, Maintenance and Inspection) PDF

Brand: MITSUBISHI
Product model: Q02CPU
Name: CPU
Sort: User's Manual (Hardware Design, Maintenance and Inspection)
File language: English
File size: 20.53MB
Input: 4 channels.
Input: DC-10~10V, DC0~20mA.
Output (resolution): 0~4000, -4000~4000, 0~12000, 0~16000, -16000~16000.
Conversion speed: 500 s/1 channel Q02CPU PDF.
18 point terminal.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller Q02CPU
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q02CPU PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required Q02CPU PDF.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. Set high performance CNC and high speed programmable controller as a whole.
Integrating the high performance CNC with the high speed programmable controller helps to shorten the overall cycle time MITSUBISHI UUser's Manual Q02CPU Manual.
Support a rich variety of FA modules, can be flexible to meet the needs of different applications.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2 MITSUBISHI User's Manual.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding maachine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q02CPU User's Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q02CPU Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
CPU unit
A2UCPU
MITSUBISHI CPU unit A2UCPU
Input and output points: 512 points. Input /
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Programmable logic controller CPU
R16CPU
MITSUBISHI Programmable logic controller CPU R16CPU
Operation control mode: stored procedure repe