LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02UCPU User's Manual (Application) PDF

MITSUBISHI Q02UCPU User's Manual (Application) PDF

Brand: MITSUBISHI
Product model: Q02UCPU
Name: PLC
Sort: User's Manual (Application)
File language: English
File size: 5.56MB
5 slots.
The main substrate needs to be equipped with CPU and power supply.
Support for high speed communication between multi CPU.
Requires 1 power modules Q02UCPU PDF.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q02UCPU
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fiields Q02UCPU PDF Q02UCPU Manual.
Can also be used in combination with the CPU module to achieve appropriate control.Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression Q02UCPU PDF.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module MITSUBISHI User's Manual.
Equipment for high temperature control stability of extrusion molding machine,
The temperature reguulating module has the function of preventing overheating and preventing over cooling Q02UCPU User's Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mmode MITSUBISHI User's Manual Q02UCPU Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
General purpose CPU
Q00UJCPU
MITSUBISHI General purpose CPU Q00UJCPU
Input / output points: 256 points. Numer of
MITSUBISHI
General purpose CPU
Q20UDHCPU
MITSUBISHI General purpose CPU Q20UDHCPU
Specification model: Q20UDHCPU. Input / outpu
MITSUBISHI
Programmable logic controller CPU
R32ENCPU
MITSUBISHI Programmable logic controller CPU R32ENCPU
Operation control mode: stored procedure repe
MITSUBISHI
General purpose CPU
Q26UDHCPU
MITSUBISHI General purpose CPU Q26UDHCPU
Input / output points: 4096 points. Numer of