Three-phase 4 wire type.
Measuring circuit number: 3 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc Q13UDVCPU PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information
Q13UDVCPU
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q13UDVCPU PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q13UDVCPU PDF.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1 MITSUBISHI User's Manual. 90U and higher) can be used to easily set parameters.Input: 4 channels.
Platinum resistance (Pt100; JPt100; Ni100).
Conversion speed: 40ms/1 channel.
18 point terminal.
Isolation between channels.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Sheddding detection function MITSUBISHI User's Manual Q13UDVCPU Manual.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type MITSUBISHI User's Manual.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent thhe loss of the program and the parameters due to forgetting to replace the battery Q13UDVCPU User's Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q13UDVCPU Manual.
The next time the power is turned on, the backup data will be automatically restored.