LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q64ADI User's Manual PDF

MITSUBISHI Q64ADI User's Manual PDF

Brand: MITSUBISHI
Product model: Q64ADI
Name: Analog-Digital Converter Module
Sort: User's Manual
File language: English
File size: 2.76MB
Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly Q64ADI PDF.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic Q64ADI
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file Q64ADI PDF. 5 slots.
Extended substrate.
No need to install power module.
Used to install Q series modules.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card Q64ADI PDF.
In the event of a CPU failure, after thhe replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q64ADI Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown MITSUBISHI User's Manual.
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control MITSUBISHI User's Manual.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run MITSUBISHI User's Manual. Control axis: maximum 8 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After staarting the specified location to stop the instruction,
Can be set in advance to stop the location Q64ADI User's Manual.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / decelleration time Q64ADI Manual.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.
Related products