Upgraded version.
Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator QD51-R24 PDF.
Synchronous encoder operation function: can use 8 synchronous encoder.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word.
Exercise basic performance is about 2 times, sports SFC processing time is reduced by about 1/4
QD51-R24
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instructionOutput: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000 QD51-R24 PDF.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark QD51-R24 PDF.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Conttrol valve can also be directly connected to analog output QD51-R24 Manual.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier MITSUBISHI User's Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules MITSUBISHI User's Manual.
Using the inter channel isolation analog module. PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI User's Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches ssaturation, it will not affect the link scan time QD51-R24 User's Manual.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selectted QD51-R24 Manual.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.