Brand: MITSUBISHI
Product model: QD62-H02 
Name: High-Speed Counter Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.28MB
Input: 4 channels.
Input: DC-10~10V, DC0~20mA.
Output (resolution): 0~4000, -4000~4000, 0~12000, 0~16000, -16000~16000.
Conversion speed: 500 s/1 channel QD62-H02  PDF.
18 point terminal.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller QD62-H02 
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output QD62-H02  PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required QD62-H02  PDF.
Without the use of inteer channel isolation analog modules QD62-H02  Manual.
Using the inter channel isolation analog module. Control axis: up to 32 axes.
Servo amplifier connection mode: SSCNET III /H (2 system).
Can be carried out with a high degree of control, free correspondence.
Large scale and medium scale system MITSUBISHI User's Manual.
Maximum number of control axis: 32 axis (Q173DSCPU), 16 axis (Q172DSCPU).
Programmable controller CPU and C language controller can be selected according to the purpose.
By using 3 sets of Q173DSCPU, 96 axes can be controlled.
Support security monitoring function, visual system MITSUBISHI User's Manual. SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Remote I/O network (remote I/O station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI User's Manual.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference QD62-H02  User's Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system QD62-H02  Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
Related products
MITSUBISHI
High speed counting module
QD62-H01
MITSUBISHI High speed counting module QD62-H01
Input: 2 channels. 50kpps. Counter input sign
MITSUBISHI
High speed counting module
QD62-H02
MITSUBISHI High speed counting module QD62-H02