LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QD75M1 User's Manual (Details) PDF

MITSUBISHI QD75M1 User's Manual (Details) PDF

Brand: MITSUBISHI
Product model: QD75M1
Name: Positioning Module
Sort: User's Manual (Details)
File language: English
File size: 8.16MB
Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +5 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series QD75M1 PDF.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password QD75M1
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights QD75M1 PDF.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000.
Output DC0~20mA; DC-12~12V QD75M1 PDF.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller MITSUBISHI User's Manual.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs havee been greatly reduced due to the need for an external isolation amplifier MITSUBISHI User's Manual QD75M1 Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module MITSUBISHI User's Manual. SRAM memory card.
RAM capacity: 256KB. Cable length 0.6 meters.
Extended substrate for connection.Compact flash memory card.
Capacity: 8GB bytes. SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference QD75M1 User's Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system QD75M1 Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
Related products
MITSUBISHI
Open collector output
QD75P2
MITSUBISHI Open collector output QD75P2
2 axes, open collector output type. 2 axis li
MITSUBISHI
Simple motion module
QD77MS16
MITSUBISHI Simple motion module QD77MS16
"Maximum control axis: 16 axis. Connection mo
MITSUBISHI
Open collector output
QD75P4
MITSUBISHI Open collector output QD75P4
4 axes, open collector output type. 2 axis /4