LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QD75MH1 User's Manual (Hardware) PDF

MITSUBISHI QD75MH1 User's Manual (Hardware) PDF

Brand: MITSUBISHI
Product model: QD75MH1
Name: Positioning Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.51MB
Input / output points: 4096 points.
Size side mode: small end mode.
SD memory card: available.
Q24DHCCPU-LS without OS.
C language controller is a long term stable supply, high reliability, high performance, flexible MELSEC on the implementation of the C language program revolutionary open platform QD75MH1 PDF.
Including pre installed VxWorks,
This C language controller can be used with various modules of the MELSEC-Q series,
Partner products and open source,
Client program assets, such as portfolio use to build a variety of systems QD75MH1
As can be used in all scenarios, can replace the computer, a new computer platform,
C MELSEC language controller stronger, simpler, higher performance, more flexible, in the future will also continue to continue to develop QD75MH1 PDF.
Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output) QD75MH1 PDF.
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces MITSUBISHI User's Manual.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start MITSUBISHI User's Manual. 8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connecteed to the CT sensor, saving wiring and space of the CT input module QD75MH1 Manual.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc MITSUBISHI User's Manual. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will sudddenly change QD75MH1 User's Manual.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) QD75MH1 Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
Simple motion module
QD77GF16
MITSUBISHI Simple motion module QD77GF16
"Maximum control axis: 16 axis. Connection mo
MITSUBISHI
Open collector output
QD75P4
MITSUBISHI Open collector output QD75P4
4 axes, open collector output type. 2 axis /4
MITSUBISHI
Open collector output
QD70P4
MITSUBISHI Open collector output QD70P4
4 axes, open collector output type. Control u