LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QD75MH2 User's Manual (Hardware) PDF

MITSUBISHI QD75MH2 User's Manual (Hardware) PDF

Brand: MITSUBISHI
Product model: QD75MH2
Name: Positioning Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.51MB
Output points: 8 points.
Output voltage and current: DC5~24A/ point; 8A/ common terminal.
OFF leakage current: 0.1mA.
Response time: 10ms.
Leaky type and source sharing QD75MH2 PDF.
18 point terminal station.
With the surge absorber.
All points of independence.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time QD75MH2
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias QD75MH2 PDF.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming QD75MH2 PDF.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file registeer,
Capacity up to 4736K words, thus simplifying the programming QD75MH2 Manual.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area MITSUBISHI User's Manual.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved MITSUBISHI User's Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc MITSUBISHI User's Manual. , can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module QD75MH2 User's Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed QD75MH2 Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
Open collector output
QD70P4
MITSUBISHI Open collector output QD70P4
4 axes, open collector output type. Control u
MITSUBISHI
Open collector output
QD70P8
MITSUBISHI Open collector output QD70P8
8 axes, open collector output type. Control u
MITSUBISHI
Open collector output
QD75P4
MITSUBISHI Open collector output QD75P4
4 axes, open collector output type. 2 axis /4