Control axis: up to 32 axes.
Servo amplifier connection mode: SSCNET III /H (2 system).
Can be carried out with a high degree of control, free correspondence QD77MS2 PDF.
Large scale and medium scale system.
Maximum number of control axis: 32 axis (Q173DSCPU), 16 axis (Q172DSCPU).
Programmable controller CPU and C language controller can be selected according to the purpose.
By using 3 sets of Q173DSCPU, 96 axes can be controlled
QD77MS2
Support security monitoring function, visual system.Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network QD77MS2 PDF.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is improved.
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened QD77MS2 PDF.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data.
QJ71GP21S-SX, CC-Link can bee used as the control station of IE QJ71GP21-SX controller network, common station MITSUBISHI User's Manual QD77MS2 Manual . 4 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle MITSUBISHI User's Manual.
To speed up the speed of positioning control to start processing.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control MITSUBISHI User's Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card. QD77MS2 User's Manual.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance QD77MS2 Manual .
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.