MITSUBISHI QJ61BT11N User's Manual PDF

Brand: MITSUBISHI
Product model: QJ61BT11N
Name: Master/Local Module
Sort: User's Manual
File language: English
File size: 8.78MB
4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station QJ61BT11N PDF.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark QJ61BT11N
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output QJ61BT11N PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required QJ61BT11N PDF.
Without the use of intter channel isolation analog modules QJ61BT11N Manual .
Using the inter channel isolation analog module.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel MITSUBISHI User's Manual.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced MITSUBISHI User's Manual.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machinne,
The temperature regulating module has the function of preventing overheating and preventing over cooling QJ61BT11N User's Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode QJ61BT11N Manual .
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
CC-Link/LT module
QJ61CL12
MITSUBISHI CC-Link/LT module QJ61CL12
Master station. Province distriution network
MITSUBISHI
CC-Link module
QJ61BT11N
MITSUBISHI CC-Link module QJ61BT11N
Master / local station sharing. Corresponding
MITSUBISHI
CC-Link module
QJ61BT11
MITSUBISHI CC-Link module QJ61BT11
Master / local station sharing. Corresponding
MITSUBISHI
CC-Link module
Q80BD-J61BT11N
MITSUBISHI CC-Link module Q80BD-J61BT11N
PCI us. Support Japanese, English OS. Master