Streamlined Communications from.
Temperature Controller to PLC.
The E5ZN Modular Temperature Controller is connected to,
the DeviceNet network.
The I/O link function allows setting and monitoring (e E5AN-HAA2HH02B-W-FLK PDF. g., of,
present values) for the E5ZN Modular Temperature Controller to,
be performed without communications programming.
Up to 16 E5ZN Modular Temperature Controllers can be,
connected to one Unit
E5AN-HAA2HH02B-W-FLK
All the parameters for the E5ZN can be uploaded or download,
ed in one operation using DeviceNet Configurator. Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two E5AN-HAA2HH02B-W-FLK PDF.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications E5AN-HAA2HH02B-W-FLK PDF.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 660 mm E5AN-HAA2HH02B-W-FLK MANUAL.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other OMRON User's Manual. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: -- OMRON User's Manual.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0 OMRON User's Manual. 3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AN-HAA2HH02B-W-FLK User's Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AN-HAA2HH02B-W-FLK MANUAL.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.