LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTR2HH03-FLK USER'S MANUAL PDF

OMRON E5CN-HTR2HH03-FLK USER'S MANUAL PDF

Brand: OMRON
Product model: E5CN-HTR2HH03-FLK
Name: Temperature Controller
Sort: USER'S MANUAL
File language: English
File size: 2.75MB
Size: M12 (Brass); Single; Shielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN E5CN-HTR2HH03-FLK PDF.
Operation mode NC.
A new generation in global applications. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M: 4m E5CN-HTR2HH03-FLK
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-HTR2HH03-FLK PDF.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1 E5CN-HTR2HH03-FLK PDF. ): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Power supplly voltage: 5 VDC E5CN-HTR2HH03-FLK MANUAL.
Output configuration: Voltage output.
Resolution (pulses/rotation): 1,000; 2,000; 3,600; 5,000; 6,000.
High-resolution Encoder OMRON USER'S MANUAL.
Incremental model.
External diameter of 55 mm.
Resolution of up to 6,000 ppr. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output OMRON USER'S MANUAL.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON USER'S MANUAL.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HTR2HH03-FLK USER'S MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HTR2HH03-FLK MANUAL.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Programmed temperature controller
E5CN-HTR2H01-FLK
OMRON Programmed temperature controller E5CN-HTR2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTR2H03D-FLK
OMRON Programmed temperature controller E5CN-HTR2H03D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTR2D
OMRON Programmed temperature controller E5CN-HTR2D
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTR2H01D-FLK
OMRON Programmed temperature controller E5CN-HTR2H01D-FLK
Size: 48 48mm, terminal type. Type: control