LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-Q2MLD-500 USER'S MANUAL PDF

OMRON E5CN-Q2MLD-500 USER'S MANUAL PDF

Brand: OMRON
Product model: E5CN-Q2MLD-500
Name: Temperature Controller
Sort: USER'S MANUAL
File language: English
File size: 2.75MB
E3F3-R81M detection methods: Regression reflection type,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyOutput configuration: DC switching NPN (normally open or closed selectable) E5CN-Q2MLD-500 PDF.
Sensing method: Through-beam E5CN-Q2MLD-500
Sensing distance: 50 cm.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material.
(metallic or non-metallic) of the objects E5CN-Q2MLD-500 PDF.
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm.
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise E5CN-Q2MLD-500 PDF. E3F3-T81M detection methods: the firiing pattern,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyNo OMRON USER'S MANUAL E5CN-Q2MLD-500 MANUAL. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: -- OMRON USER'S MANUAL.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 OMRON USER'S MANUAL. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-Q2MLD-500 USER'S MANUAL.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-Q2MLD-500 MANUAL.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Foundation type temperature controller
E5CN-Q2HH03TD-FLK
OMRON Foundation type temperature controller E5CN-Q2HH03TD-FLK
The main ody: terminal type, temperature inp
OMRON
Basic-type Digital Temperature Controller
E5CN-Q2TU
OMRON Basic-type Digital Temperature Controller E5CN-Q2TU
Size: 1/16 DIN. Case color: Black. Power su
OMRON
Foundation type temperature controller
E5CN-Q2TD
OMRON Foundation type temperature controller E5CN-Q2TD
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-Q2HBTD-W
OMRON Foundation type temperature controller E5CN-Q2HBTD-W
The main ody: terminal type, temperature inp