Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type E5CN-R2LD PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E5CN-R2LD
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10 E5CN-R2LD PDF. 5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CN-R2LD PDF.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately) OMRON User's Manual. Easy and optimum settings for anyone.
Smart Fiber Amplifier Unit with Long-term Stable Detection.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button.
Highly usabble design enables anyone to configure the settings easily OMRON User's Manual E5CN-R2LD MANUAL.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II). Size: 96 × 96 mm OMRON User's Manual.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When usingg models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-R2LD User's Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5CN-R2LD MANUAL.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.