LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-R2TU User's Manual (Communications Functions) PDF

OMRON E5CN-R2TU User's Manual (Communications Functions) PDF

Brand: OMRON
Product model: E5CN-R2TU
Name: Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 0.55MB
E3JK-R32 regression reflection type,
E3JK direct current mode: mode; ON,
Miniature amplifier built-in type photoelectric switchSize: 48 x 96mm.
Category: power AC100 ~ 240V with E5CN-R2TU PDF.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5CN-R2TU
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-422 E5CN-R2TU PDF.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
CCan be set up to 8 procedures (mode) x 32 (step) procedure E5CN-R2TU MANUAL.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5CN-R2TU PDF.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV OMRON User's Manual.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication OMRON User's Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. The use of OMRON''s original polarized multilayer film technology (FAO) can not be affected by the color of the workpiece, the subtle difference between the brightness of the stable detection OMRON User's Manual E5CN-R2TU User's Manual.
Simply press the button to adjust the teaching method.
2 types of fiber optic probes are used to correspond to a wide range of applications.
The pulse lighting mode is not easily affected by external light.
Thhe detection principle of the gloss of FAO E5CN-R2TU MANUAL.
The use of fuzzy teaching function to test the stability of the response.
Multiple bending countermeasures.
Related products
OMRON
Foundation type temperature controller
E5CN-C2L
OMRON Foundation type temperature controller E5CN-C2L
Ontology: terminal type, analog input type. C
OMRON
Foundation type temperature controller
E5CN-CQ2HT
OMRON Foundation type temperature controller E5CN-CQ2HT
The main ody: terminal type, temperature inp
OMRON
High performance temperature controller
E5CN-HC2B
OMRON High performance temperature controller E5CN-HC2B
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Programmed temperature controller
E5CN-HTC2BFD
OMRON Programmed temperature controller E5CN-HTC2BFD
Size: 48 48mm, terminal type. Type: control