Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: double alarm.
Output: voltage output (solid state relay driver).
Digital universal dual display electronic temperature controller E5CN-RTDU PDF.
DIN 48 * 48mm manual automatic tuning (Auto-tuning Manual) PID control.
Double alarm / single alarm and temperature resistance antibody species rich.
Relay / solid state relay (SSR drive) series
E5CN-RTDU
To prevent misuse function. Size: 48 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V E5CN-RTDU PDF.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set E5CN-RTDU PDF.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications OMRON USER'S MANUAL.
Slender fusellage depth 60mm E5CN-RTDU MANUAL.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control OMRON USER'S MANUAL. Sensing method: Retro-reflective Sensors.
Appearance: Horizontal.
Connection method: Connector(M12).
Sensing distance: 7 m.
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Ontology: terminal type, analog input type OMRON USER'S MANUAL.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-RTDU USER'S MANUAL.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-RTDU MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.