Brand: OMRON
Product model: E5CN-RTUAC100-240
Name: Temperature Controller
Sort: USER'S MANUAL
File language: English
File size: 2.75MB
Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V E5CN-RTUAC100-240 PDF.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: - E5CN-RTUAC100-240
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E5CN-RTUAC100-240 PDF.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately) E5CN-RTUAC100-240 PDF.
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) OMRON USER'S MANUAL.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve E5CN-RTUAC100-240 MANUAL. Size: 48 x 96mm.
Category: power AC100 ~ 240V with OMRON USER'S MANUAL.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON USER'S MANUAL.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the staate of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-RTUAC100-240 USER'S MANUAL.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5CN-RTUAC100-240 MANUAL.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Rotating pulse meter
K3HB-RPB-CPAC21 AC100-240
OMRON Rotating pulse meter K3HB-RPB-CPAC21 AC100-240
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Temperature Monitoring Relay
K8AB-TH12S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH12S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Supply vol