Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver E5EN-C3BTD-W-N PDF.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function
E5EN-C3BTD-W-N
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5EN-C3BTD-W-N PDF.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5EN-C3BTD-W-N PDF.
Increased the 3 segment displlay, which can display the current value / target / operation E5EN-C3BTD-W-N MANUAL.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation OMRON User's Manual. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, --;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3T-FD@@M (8).
Page: Dimensions, 15. Specification: Resin, standard type.
Shaft interior (tolerance *) exterior dia: 2 dia OMRON User's Manual. (Height: 8), 9 dia.
Couplings.
Coupling Materials and Characteristics.
OMRON provides two types of couplings for different.
application conditions: Resin and metal.
Select the best type for the application. Type: High-speed response models.
Connecting method: Pre-wired (2 m) OMRON User's Manual.
Model: PNP output.
Applicable wire-saving connector(sold separately): Type,--; Model,--.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximately 20 years.
Power turrning to easily set the optimum light level E5EN-C3BTD-W-N User's Manual.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even for low-reflective objects and large objects E5EN-C3BTD-W-N MANUAL.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit.