Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling E5EN-HTAA2HHBFMD-500 PDF.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: -
E5EN-HTAA2HHBFMD-500
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5EN-HTAA2HHBFMD-500 PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5EN-HTAA2HHBFMD-500 PDF.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver OMRON User's Manual. 4.0 CX-Thermo) to carry ouut a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5EN-HTAA2HHBFMD-500 MANUAL.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Control output: relay output.
Auxiliary output: 2 points OMRON User's Manual.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON User's Manual.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter ccable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EN-HTAA2HHBFMD-500 User's Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5EN-HTAA2HHBFMD-500 MANUAL.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).