LK166
Home >> Download >> OMRON >> Manual Download >> OMRON C500-RM001-PEV1 User's Manual PDF

OMRON C500-RM001-PEV1 User's Manual PDF

Brand: OMRON
Product model: C500-RM001-PEV1
Name: Safety Light Curtain
Sort: User's Manual
File language: English
File size: 1.04MB
Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 4 axes C500-RM001-PEV1 PDF.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.36A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes C500-RM001-PEV1
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control C500-RM001-PEV1 PDF. Name: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes.
Standards: UC1, N, L, CE C500-RM001-PEV1 PDF.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. CPU Unit: Units with 10 I/O points.
I/O terminal block.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: --.Product: DeviceNet Unit OMRON User's Manual.
Specifications: For CS Series,
Functions as either a master or a slave.
2,048 I/O points.
Standards: UC1, N, L, CE.
A DeviceNet Unit for the CS Series.
That Boasts Industry-leading.
Performance and Functions. Unit type: CS1 Special I/O Units C500-RM001-PEV1 Manual.
Product name: Isolated-type DC Input Unit OMRON User's Manual.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A OMRON User's Manual.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems C500-RM001-PEV1 User's Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C500-RM001-PEV1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Related products
OMRON
SYSBUS Remote I/O Unit
C500-RM001-V1(3G2A5-RM001-V1)
OMRON SYSBUS Remote I/O Unit C500-RM001-V1(3G2A5-RM001-V1)
C500-RM SYSMAC BUS Remote I/O Master Wired C5
OMRON
SYSBUS Remote I/O Unit
C500-RM201(3G2A5-RM201)
OMRON SYSBUS Remote I/O Unit C500-RM201(3G2A5-RM201)
C500-RM SYSMAC BUS Remote I/O Master Wired C5
OMRON
SYSBUS Remote I/O Unit
C500-RM001-PV1(3G2A5-RM001-PEV1)
OMRON SYSBUS Remote I/O Unit C500-RM001-PV1(3G2A5-RM001-PEV1)
C500-RM SYSMAC BUS Remote I/O Master Wired C5