Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output E5AC-TCX4DSM-065 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -
E5AC-TCX4DSM-065
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5AC-TCX4DSM-065 PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV statte display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV E5AC-TCX4DSM-065 PDF E5AC-TCX4DSM-065 Manual.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON User's Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. The small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance OMRON User's Manual.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition OMRON User's Manual.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connectioon method can be selected from a screw terminal and a PUSH-IN fastening terminal E5AC-TCX4DSM-065 User's Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5AC-TCX4DSM-065 Manual.
It can be easily set by CS-Thermo (sold separately).