Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Auxiliary outputs: 1.
Control output 1: Current output E5AN-HSS2HH03BF-FLK PDF.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0
E5AN-HSS2HH03BF-FLK3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AN-HSS2HH03BF-FLK PDF.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Size: 96 x 96mm E5AN-HSS2HH03BF-FLK PDF.
Category: powerr AC100 ~ 240V with E5AN-HSS2HH03BF-FLK Manual.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON User's Manual.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON User's Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP OMRON User's Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes thhe process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AN-HSS2HH03BF-FLK User's Manual.
Through the infrared port can be carried out from the frront of the communication E5AN-HSS2HH03BF-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.