Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: -- E5AN-HSS2HHBFD PDF.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
E5AN-HSS2HHBFD Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 E5AN-HSS2HHBFD PDF. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AN-HSS2HHBFD PDF.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 OMRON User's Manual. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs E5AN-HSS2HHBFD Manual. Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference OMRON User's Manual.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator. Ontology: terminal type, analog input type.
Type: control output 2 point type (power AC/DC24V) OMRON User's Manual.
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E5AN-HSS2HHBFD User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5AN-HSS2HHBFD Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.