Control output 1: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: --.
Power supply voltage: 24 VAC/VDC E5AR-TC43DW-FLK PDF.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15
E5AR-TC43DW-FLK2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature E5AR-TC43DW-FLK PDF.
Controllers to each other. Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: ON/OFF action.
Output: relay.
Input: platinum resistance Pt100.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode E5AR-TC43DW-FLK PDF.
And the reset function is added.
Through the installation of the adapter can be continuously close.
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Element type: J (IC).
Terminal type: Exposed-terminal Models OMRON User's Manual.
Protective tubing diameter D (mm): 12 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON User's Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. E32-D15ZR type: stanndard type; soft (new standard),
Specialty: the plane shape of head,
Bending radius (mm): R; R1 OMRON User's Manual E5AR-TC43DW-FLK Manual.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSize: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5AR-TC43DW-FLK User's Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault