Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V E5CN-C2MTD-500 PDF.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -
E5CN-C2MTD-500
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E5CN-C2MTD-500 PDF.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately) E5CN-C2MTD-500 PDF.
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness iis only 60mm E5CN-C2MTD-500 Manual.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) OMRON USER'S MANUAL.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Programmable Controllers Join the Series!
Program up to 256 segments and take advantage of the high cost performance,
of the new LCD that improves both the field of view and contrast OMRON USER'S MANUAL.
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0.01°C display.
High-speed sampling cycle of 60 ms OMRON USER'S MANUAL.
High Accuracy.
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller. Models,
also available with Remote SP.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SV.
Flexiblle contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version,
4 E5CN-C2MTD-500 USER'S MANUAL. 3). Program settings can be managed.
An infrared ports enables communications from the front panel.
Preventtive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E5CN-C2MTD-500 Manual.
Model available with position-proportional control.