LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HQ2HH03-FLK User's Manual PDF

OMRON E5CN-HQ2HH03-FLK User's Manual PDF

Brand: OMRON
Product model: E5CN-HQ2HH03-FLK
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 4.04MB
E3JK-R82 regression reflection type,
E3JK direct current mode: mode; shading ON,
Miniature amplifier built-in type photoelectric switchE32-T12L type: special beam type; long range / high function,
Specialty: diameter 3 cylinder,
Shape / detection distance (mm): 1700; 1330; 870 (350),
Bending radius (mm): R25 E5CN-HQ2HH03-FLK PDF.
Standard test object (minimum test object) (mm) 1: 1.4 (0.01),
Fiber element for meeting diversified needsName: Basic Unit (temperature control) *1 E5CN-HQ2HH03-FLK
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking) E5CN-HQ2HH03-FLK PDF.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
Communications functions: G3ZA connection porrt: RS-485,
From End Unit: Port A or port B: RS-485 E5CN-HQ2HH03-FLK Manual.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel E5CN-HQ2HH03-FLK PDF.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application OMRON User's Manual.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements OMRON User's Manual.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method OMRON Usser's Manual E5CN-HQ2HH03-FLK User's Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
NNon polar proximity sensor E5CN-HQ2HH03-FLK Manual.
Type: DC three wire / connector type.
Shape: shield, M12.
Detection range: 2mm.
Output configuration: NPN.
Action mode: NC.
Related products
OMRON
High performance temperature controller
E5CN-HQ2H03-FLK
OMRON High performance temperature controller E5CN-HQ2H03-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2HH03-FLK
OMRON High performance temperature controller E5CN-HR2HH03-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HQ2D
OMRON High performance temperature controller E5CN-HQ2D
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
High performance temperature controller
E5CN-HQ2H03D-FLK
OMRON High performance temperature controller E5CN-HQ2H03D-FLK
Size: 48 x 48mm. Body: terminal type. Type: c