LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HR2HH03D-FLK User's Manual (Communications Functions) PDF

OMRON E5CN-HR2HH03D-FLK User's Manual (Communications Functions) PDF

Brand: OMRON
Product model: E5CN-HR2HH03D-FLK
Name: Digital Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 1.00MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 2m E5CN-HR2HH03D-FLK PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-HR2HH03D-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models E5CN-HR2HH03D-FLK PDF.
Protective tubing diameter D: 4.8 dia.
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CCN-HR2HH03D-FLK PDF E5CN-HR2HH03D-FLK Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON User's Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON User's Manual.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON User's Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HR2HH03D-FLK User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HR2HH03D-FLK Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
High performance temperature controller
E5CN-HR2
OMRON High performance temperature controller E5CN-HR2
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2H03D-FLK
OMRON High performance temperature controller E5CN-HR2H03D-FLK
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
High performance temperature controller
E5CN-HR2HH03-FLK
OMRON High performance temperature controller E5CN-HR2HH03-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2H01D-FLK
OMRON High performance temperature controller E5CN-HR2H01D-FLK
Size: 48 x 48mm. Body: terminal type. Type: c