LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTR2MD-500 USER'S MANUAL PDF

OMRON E5CN-HTR2MD-500 USER'S MANUAL PDF

Brand: OMRON
Product model: E5CN-HTR2MD-500
Name: Digital Temperature Controller
Sort: USER'S MANUAL
File language: English
File size: 2.91MB
The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: current output E5CN-HTR2MD-500 PDF.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CN-HTR2MD-500
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-HTR2MD-500 PDF.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5CN-HTR2MD-500 PDF. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Descripption, Holder/bracket, Shaft (brace),
Bolt with hexagonal hole, Nut, Phillips screw, Slotted/Phillips screws;
Material, PBT (polybutylene tereph thalate), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304);
Count, 1, 1, 1, 1, 1, 2 OMRON USER'S MANUAL E5CN-HTR2MD-500 Manual.
Applicable sensor (mounting pitch on sensor side): E3Z (25 OMRON USER'S MANUAL. 4),
E3S-R6@/R8@ (20) , E39-R3.
Page: Dimensions, 14. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points OMRON USER'S MANUAL.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furrther performance improvement E5CN-HTR2MD-500 USER'S MANUAL.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-HTR2MD-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Programmed temperature controller
E5CN-HTQ2H03-FLK
OMRON Programmed temperature controller E5CN-HTQ2H03-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQ2H01-FLK
OMRON Programmed temperature controller E5CN-HTQ2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTC201-FLK
OMRON Programmed temperature controller E5CN-HTC201-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTC203-FLK
OMRON Programmed temperature controller E5CN-HTC203-FLK
Size: 48 48mm, terminal type. Category: con