Appearance: M8.
Sensing distance: 2 mm.
Connection method: M12 Pre-wired Smartclick Connector Models (0.3m).
Cable specifications: PUR (increased oil-resistant) E5CN-HV2MD-500 PDF.
Polarity: Yes.
Operation mode : NC.
Pin arrangement: 1: +V, 2: 0 V.
Applicable connector code: H.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E5CN-HV2MD-500
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil E5CN-HV2MD-500 PDF.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 35cm E5CN-HV2MD-500 PDF.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON User's Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple OMRON User's Manual.
Alarm points: -.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple OMRONN User's Manual E5CN-HV2MD-500 Manual.
Sampling time was reduced to 250ms. Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remoote SP input, suitable for a wide range of applications E5CN-HV2MD-500 User's Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5CN-HV2MD-500 Manual.
A new type of proportional control allows you to control the valve.