Sensor type: Retro-reflective with MSR function.
Sensing distance: 0.1 to 4 m with E39-R1S.
Connection method: pre-wired.
Model: PNP output.
A new generation in sensing performance E5CN-Q2HBL PDF.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection
E5CN-Q2HBL
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver) E5CN-Q2HBL PDF.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 1 points.
Remote SP input: -.
Transfer output: - E5CN-Q2HBL PDF.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms OMRON User's Manual.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmiission output,
Remote SP input function, support for a variety of applications E5CN-Q2HBL Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer OMRON User's Manual.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON User's Manual.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increasedd,
Further performance improvement E5CN-Q2HBL User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-Q2HBL Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.