OMRON E5CN-R1TU User's Manual (Basic Type) PDF

Brand: OMRON
Product model: E5CN-R1TU
Name: Temperature Controller
Sort: User's Manual (Basic Type)
File language: English
File size: 6.14MB
Sensing method: Retro-reflective with MSR function.
Connection method: Connector(M8, 4 pins).
Response time: 1 ms.
Sensing distance: 15 m (300 mm) (Using E39-R1),
7 m(200 mm)(Using E39-R12), 7 m (200 mm)(Using E39-R6) E5CN-R1TU PDF.
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color E5CN-R1TU
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) E5CN-R1TU PDF.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5CN-R1TU PDF.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON User's Manual E5CN-R1TU Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON User's Manual. Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON User's Manual.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-R1TU User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-R1TU Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Programmed temperature controller
E5CN-HTC2BF
OMRON Programmed temperature controller E5CN-HTC2BF
Size: 48 48mm, terminal type. Category: con
OMRON
Foundation type temperature controller
E5CN-R2T-W
OMRON Foundation type temperature controller E5CN-R2T-W
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-CQ203T-FLK
OMRON Foundation type temperature controller E5CN-CQ203T-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-C203TD-FLK
OMRON Foundation type temperature controller E5CN-C203TD-FLK
The main ody: terminal type, temperature inp