Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive E5CN-R2HH03T-W-FLK PDF.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E5CN-R2HH03T-W-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-R2HH03T-W-FLK PDF. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points E5CN-R2HH03T-W-FLK PDF.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater usee E5CN-R2HH03T-W-FLK Manual.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON USER'S MANUAL.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON USER'S MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc OMRON USER'S MANUAL. , can be a key operation. Control output 1: Relay output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operationn E5CN-R2HH03T-W-FLK USER'S MANUAL.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm E5CN-R2HH03T-W-FLK Manual.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.