Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: there.
Output: relay output.
Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID control E5EN-C3TD-N PDF. "Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive
E5EN-C3TD-N
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-C3TD-N PDF.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 E5EN-C3TD-N PDF. 6 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON User's Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensing method: Through-beam (Emitter + Reeceiver) OMRON User's Manual E5EN-C3TD-N Manual.
Connection method: Pre-wired (2 m).
Sensing distance: 15m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models OMRON User's Manual.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.
Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,,
Further performance improvement E5EN-C3TD-N User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EN-C3TD-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.