Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, Slotted/Phillips screws M4 × 25,
Spring washer M4, Plain washer M4, Nuts M4;
Material, Stainless steel (SUS304), Stainless steel (SUS304),
Stainless steel (SUS304), Stainless steel (SUS304);
Count, 2; 2; 2; 2 E5EN-HSS2HBM-500 PDF.
Applicable sensor (mounting pitch on sensor side): E3G-R1@ (25), E3G-L7@ (25).
Page: Dimensions, 13
E5EN-HSS2HBM-500 Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference E5EN-HSS2HBM-500 PDF.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator. Ultra small rotary encoder (diameter 20) - absolute.
Machine built in super small E5EN-HSS2HBM-500 PDF.
The diameter of 220mm size, resolution 256 (8bit) E5EN-HSS2HBM-500 Manual.
Axle and hollow shaft type.
Power supply voltage: DC5V.
Output form: NPN open collector output.
Resolution (segmentation):256.
Axis shape: shaft extension. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) OMRON User's Manual.
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output) OMRON User's Manual.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 OMRON User's Manual. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5EN-HSS2HBM-500 User's Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault