Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 1 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max E5EN-HTAA3BFM-500 PDF. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color
E5EN-HTAA3BFM-500
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EN-HTAA3BFM-500 PDF.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E5EN-HTAA3BFM-500 PDF.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PPV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-HTAA3BFM-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON User's Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON User's Manual.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5EN-HTAA3BFM-500 User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-HTAA3BFM-500 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.