Sensing method: Retro reflective.
Appearance: Vertical.
Connection method: Standard M12 Connector.
Sensing distance: 1m [100 mm].
Model: NPN output E5EN-HTPRR2BBFD PDF.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, --.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards
E5EN-HTPRR2BBFD Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection range: red light 500mmmm.
Output mode: PNP output. Size: 48 x 48mm E5EN-HTPRR2BBFD PDF.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - E5EN-HTPRR2BBFD PDF.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance OMRON User's Manual.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors OMRON User's Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5EN-HTPRR2BBFD Manual.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: 96 x 96mm OMRON User's Manual.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5EN-HTPRR2BBFD User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-HTPRR2BBFD Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.